Privacy Policy — BMB SX3Y Phone
Effective date: November 26, 2026
This document is the public privacy policy for the BMB SX3Y Phone app. It also describes how to connect an S/X module (J1 / FTDI or Wio Terminal) and how to flash the Wio Terminal. The firmware sketch itself is not published on this page — get it from the app (Settings → Terminal).
1. About the app
BMB SX3Y Phone is a tool for bench and pack diagnostics of Tesla Model S / Model X battery modules (BMB) and Tesla Model 3 / Model Y modules (3Y): brick voltages, TVSH, statuses, and live monitoring.
- USB FTDI (OTG) — S/X modules: phone ↔ OTG ↔ FTDI adapter ↔ module J1
- BLE (Wio Terminal) — phone ↔ Bluetooth ↔ Wio with MASC-BMB firmware ↔ module (S/X over UART; 3Y board path separately)
- Wio modes in the app: Single Module SX, Battery Pack SX, 3Y Modules (23S / 25S brick map UI)
Module data is read locally on the device. The app is not designed to upload full battery logs to MASCorp servers.
2. How to connect by pins — USB FTDI (S/X)
Direct phone connection for Model S / Model X modules over USB FTDI.
You need: an Android phone with USB OTG, an FTDI adapter with the jumper set to 5V, and a cable/pin wiring to the module J1 connector (Molex 15-97-5101, 2×5).
Important: follow pin numbers, not wire colors — colors may differ between harnesses.
2.1 J1 → FTDI pinout
| J1 pin | Signal | On FTDI | Note |
|---|---|---|---|
| Pin 1 | 5V | 5V / VCC | FTDI jumper on 5V |
| Pin 3 | GND | GND | Common ground |
| Pin 2 | UART A (module TX) | RXD | Module response |
| Pin 9 | UART B (module RX) | TXD | Commands from the phone |
Pins 4 / 5 / 7 / 8 are not used for FTDI. Do not connect pins 6 and 10 (FAULT) to FTDI.
2.2 Steps on the phone
- Enable OTG and connect FTDI to the phone
- In the app, select USB FTDI → Connect
- Allow USB access when Android asks
- If there is no response — swap only Pin 2 ↔ Pin 9 on the RXD/TXD side
Important
Do not rely on harness twists: power = Pin 1 + Pin 3, UART = Pin 2 + Pin 9.
One harness “tail” goes to the module; the other stays unconnected.
There must not be ≈0.5 Ω between Pin 2 and Pin 9 (that is a UART short).
5V on Pin 1 powers the isolator; the module cells are still required.
3. How to connect to the Wio Terminal
Wio is the preferred path for bench work with live UI on the terminal plus phone control over BLE. Use the same J1 pin numbers as FTDI; UART must go through a 3.3 V ↔ 5 V level shifter (Wio logic is 3.3 V).
3.1 Wio → J1 (S/X modules)
| Wio (40-pin / Serial1) | Signal | J1 pin | Note |
|---|---|---|---|
| Pin 2 / 4 | 5V | Pin 1 | Powers the isolator |
| GND (e.g. Pin 6 / 9) | GND | Pin 3 | Common ground |
| Pin 8 · TX (Serial1) | UART out | Pin 9 (module RX) | Via level shifter |
| Pin 10 · RX (Serial1) | UART in | Pin 2 (module TX) | Via level shifter |
- Baud on S/X is ~612500 (or 631578 on newer boards) — the sketch sets this
- If there is no UART reply — swap only the two UART wires
- Do not leave FTDI TX and Wio TX on the same bus at the same time
- FAULT pins 6 / 10 stay unused
3.2 Phone ↔ Wio over BLE
- Power the Wio (USB-C or 5V) with MASC-BMB firmware already loaded (see §4)
- On the Wio screen you should see the MASC-BMB UI; BLE advertising name is
MASC-BMB - In the app choose BLE (Wio Terminal) → allow Bluetooth / nearby devices
- Wait until the pairing radar locks on
MASC-BMB - Pick a mode: Single Module SX, Battery Pack SX, or 3Y Modules
3.3 3Y modules
Model 3 / Y modules do not use the S/X J1 UART pinout. They go through a separate isoSPI / Batman board path into the Wio. The phone UI for 3Y Modules (23S / 25S map) is already in the app; the physical 3Y board pinout will be expanded here when that hardware path is published. Until then, use Wio + J1 for S/X as above.
4. How to flash the Wio Terminal
Firmware stays in the app
We do not publish the sketch as a public download on this privacy page. Open BMB SX3Y Phone → Settings → Terminal → Download Wio Terminal firmware (MASCorp login required). That gives you the Arduino sketch package for your account.
- In the app: Settings → Terminal → Download Wio Terminal firmware (password-protected zip with
MASC_BMB/MASC_BMB.ino) - Open the zip with password = your account login (email)
- Install Arduino IDE
- Install board support: Seeed SAMD Boards → select board Seeed Wio Terminal
- Install required libraries used by the sketch: TFT_eSPI (Wio Terminal profile) and the Seeed rpcBLE / BLE stack (
BLE2902) - Open
MASC_BMB.inofrom the downloaded folder - Connect the Wio with a USB-C data cable → choose the COM/serial port → Upload
- After reboot, the Wio should show the MASC-BMB picker / Live UI and advertise as
MASC-BMBfor the phone
Tips
Use a data-capable USB-C cable (charge-only cables will not enumerate a port).
If Upload fails, double-press the Wio reset button to enter the bootloader, then try again.
After a successful flash, pair from the phone as in §3.2 — you do not need FTDI for normal Wio work.
5. Data summary
On sign-in, the app sends your login and password to MASCorp Diagnostics servers for authentication only (plus a routine account launch report, same as other MASCorp apps). The same login is used when the app downloads the Wio firmware package for your account.
The password is stored on the device in encrypted form (Android Keystore). Theme preference is stored locally.
Communication with the battery module goes over USB or BLE on your device. We do not sell personal data and do not build advertising profiles from diagnostics.
If you do not agree with this policy — do not use the app.
6. What data is processed
6.1 Online authentication
On sign-in to MASCorp servers, the following may be sent: email (login), password for verification, app name (BMB SX3Y Phone), and platform (Android). Storage on the server follows MASCorp account rules.
6.2 Local work with the module
Brick voltages, statuses, TVSH, and module service responses are processed on the phone for monitoring screens. The app is not designed to upload full battery dumps to the MASCorp cloud in the normal workflow.
6.3 Storage on the device
- Login and encrypted password (Android Keystore)
- Light / dark theme preference
6.4 Technical logs
For server security, IP address and basic request metadata may be briefly recorded at sign-in and at authenticated firmware download. There is no separate advertising analytics in the app.
7. How data is used
- Account sign-in and license / access checks
- Delivering the Wio firmware package to signed-in users
- Running diagnostics features on the device
- Protecting the service from abuse
- Compliance with law when required
8. Sharing with third parties
We do not sell personal data. Data may be processed by hosting infrastructure and MASCorp payment / account services to the extent needed to run the account portal. Google Play and the device manufacturer handle installation and permissions under their own policies.
9. Your rights
Depending on your jurisdiction, you may request access to, correction of, or deletion of account data at mondialautoservicecorp@gmail.com. Uninstalling the app from the phone removes the app’s local data.
10. Changes
We may update this page. The current version is always at https://mascorpdiagnostics.com/bmbsx/privacy. The date at the top is the date of the last material revision.
11. Contact
MASCorp Diagnostics · mondialautoservicecorp@gmail.com
Tesla® is a registered trademark of Tesla, Inc. BMB SX3Y Phone is an independent application and is not affiliated with Tesla, Inc.